COBHAM SOLO4 Especificações Página 81

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 99
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 80
81
Control Commands
The OSD page can be changed remotely using RS232 control
commands, or by using the Receiver Control Application (see section
8.3). Relevant commands are shown below; please refer to the section
15 for how to use control commands.
Relevant Command List
Function
R/W
Block
Command
Data
Type
On Screen
Display
r/w
g
osd
0 = Off
1 = Channel A
2 = Channel B
3 = Channel C
4 = Channel D
List
On Screen
Display Page
r/w
g
osp
0 = Original
1 = Input Status
2 = RF Advanced
3 = Engineering Data
4 = Frequency Scan
5 = GPS Overlay
List
On Screen
Display Timeout
r/w
g
ost
OSD timeout in
seconds
Integer
Frequency
Scan Range
Minimum
r/w
g
smi
Starting frequency for
scan in GHz
Double
Frequency
Scan Range
Maximum
r/w
g
sma
Ending frequency for
scan in GHz
Double
Frequency
Scan
Resolution
r/w
g
sre
Resolution of
frequency scan in MHz
Double
The page displayed depends on a combination of the On Screen
Display (osd) value and the On Screen Display Page (osp) value.
If showing the Original OSD page the spectrum plot will correspond to
the On Screen Display (osd) value.
If showing the new Engineering Data page, the spectrum plots will
correspond to:
A and B if On Screen Display (osd) value = 1 or 2
C and D if On Screen Display (osd) value = 3 o
r 4
C and D will only be displayed if available.
osd = 0?
No OSD
osp = 0?
Show original OSD
Show corresponding
new OSD page
Yes
Yes
No
No