Control Cable
The control cable is used for connecting the SOLO receiver to a PC
when using the domo PC control application. The PC control
application is described in more detail the Advanced Operation section
of this handbook.
Data Connection
The SOLO receiver features a general purpose DATA port used for
outputting RS232 data transmitted from a SOLO2/4 transmitter.
Installation Notes
The domo SOLO receiver has been designed so that the down-
con
verter units are mounted remotely from the receiver unit, and
connected via the 3 metre TNC cable.
The down-converter units should be connected directly to the receive
antenna, but where this is not possible a short length of low loss RF
cable such RG213C/U should be used. System performance will be
degraded by the introduction of RF losses at this point.
The down converter should be screwed or strapped
to a flat surface or
pole, using the integral mounting holes on the unit. The down converter
is weather proof, and has no special cooling requirements. If the down-
converter is mounted where it is exposed to the weather then the
connector labelled ‘ANT / IN’ should face upwards.
The antenna itself should be separately secured, the TNC connectors
should not be expected to take the strain of the anten
na.
The domo SOLO2/SOLO4 receiver is designed to be mounted in an
equipment rack or shelter and must not be exposed to the elements.
The receiver is splash resistant, but is not waterproof, so it should not be
exposed to moisture for prolonged periods.
The receiver is self-cooling; however it should be mounted in a
ventilated environment. Forced air cooling is not required. Adequate
clearance on either
side the receiver (5cm) should be allowed for
ventilation.
The receiver is supplied with a mounting plate that allows the unit to be
screwed or strapped to a flat surface.