The assembled system is shown below.
DC Power and Control Cable
The SOLAMP is powered by the SOL2/SOL4 TX and no additional
power is required. However the voltage range when using the SOLAMP
is more limited.
Input Voltage Range: 11-16V, reverse voltage protected.
Current Draw 1.2A (Includes SOL2/SOL4 TX) at 12V.
Antennas
Domo SOLAMP is supplied without antennas as standard. It is good
practice to ensure that an antenna is always connected before powering
the device. Pr
olonged operation without an antenna is not
recommended. The antenna should be connected by screwing it to the
TNC Type output connector with adapters as required, but care should
be taken not to over-tighten.
Note: It Is recommended that where possible antennas should be connected
directly to the SOLAMP. Use of cables will degrade performance.