IP Address
This control allows the user to change the IP address of the unit. The
factory default value is 192.168.0.71.
The user should make a note of the unit’s new IP address when
changing it. Failure to do so will result in an inability to use the web
browser interface until the unit’s new IP address is recovered.
Multicast Address
This control allows the user to change the multicast address used by the
unit. The default valu
e is 239.16.33.254.
Port Number
This control allows the user to change the multicast port used by the
unit. The default value is 10000.
TTL
This control allows the user to change the value of the IP TTL (Time to
Live) set by the unit.
SAP Address
This control allows the user to change the value SAP/ SDP multicast
address used by the unit. The default value is 224.2.127.254 and the
port used is 9875. These are standard multicast
values for such
parameters, and it is recommended they are not changed unless
specifically required due to routing restrictions.
SAP / SDP Data
Note – SAP is Session Announcement Protocol and SDP is Session Description Protocol
as defined in RFC2327 and RFC2974
• Service Name – textual information naming the multicast stream as
delivered in the SAP/SDP packets from the unit. Default is “MPEG
Stream”
• Info – further textual information about the multicast stream as delivered
in the SAP/SDP packets from the unit. Default is “NetEng”
• Description - Optional URI (Universal Resource Identifier) pointing to a
web page on the network containing additional informati
on about the
multicast. Default is www.domo.co.uk
• Bitrate - textual information indicating the bitrate in kbits/s of the stream.
Default is usr kbit/s