Chapter 2: Installation
98-141368-A 33
To connect the data indicator lamp
The data indicator lamp is used to show if there is an active data connection.
Specifications for the lamp:
Colour: Orange
•Operating voltage: 12 VDC
Operating current: 7/14 mA ±15%
The below procedure is an example with default configuration of I/O pins, and the lamp is
on when a data connection is active.
1. Solder your wires to pin X1 and X2 on the lamp.
2. Mount the lamp in the location you want and tighten the nut (max. torque 50 Ncm).
3. Connect the wire from pin X1 to pin 3 on the I/O connector.
4. Connect the wire from pin X2 to pin 7 on the I/O connector.
When a data connection is active, the lamp is on.
X1, Negative polarity
X2, positive polarity